Basic Camera
When talking about real-time capability there is the absolute latency time and there is a time jitter. The time jitter defines how much the time varies betw...
Wed, 28 Aug, 2019 at 5:31 PM
The answer is yes. For Basler area scan camera, there is a function called "Stacked ROI" that allow you to do a selection on multiple Regions of...
Mon, 26 Aug, 2019 at 4:10 PM
For Bayer pixel format. If the color camera uses one of the Bayer pixel formats, it outputs 8, 10, or 12 bits of data per pixel. The pixel data is not proce...
Tue, 27 Aug, 2019 at 10:46 AM
“C-Mount” lenses have a flange back distance of 17.526mm whereas “CS-Mount” have 12.5mm. C-Mount lenses can be used on CS-Mount cameras by utilizing a 5m...
Wed, 18 Sep, 2019 at 1:46 PM
Can. Use an 5mm spacer ring together with the C-Mount lens and then connect to your camera.
Wed, 18 Sep, 2019 at 1:47 PM
The camera can be operated above ambient temperature, but there'll be problems such as noise & malfunction. The noise is doubled for every 6 degrees...
Mon, 7 Oct, 2019 at 1:57 PM
Question: Device link throughput limit: - Does it actually slow down the transmission speed between the camera and card? - i.e. does it use a slower freque...
Fri, 28 Feb, 2020 at 4:39 PM
Question: - Does the camera's IO have a time delay function? Answer: - Yes, there is a frame start trigger delay that allows you to specify a del...
Mon, 23 Mar, 2020 at 5:23 PM
Question: - What is the average and peak current consumption for acA1440-220uc? Answer: For acA1440-220uc: - Average current consumption is 660mA -...
Tue, 24 Mar, 2020 at 10:12 AM
Question: - What is the min voltage for the input signal to trigger the camera? Answer: - For optocoupler input, min trigger voltage = 2.2V. - For GP...