Problem:
- Basler camera with cognex AIK Driver, long capturing time. 70ms for acA-4096-40uc with RBG output, basler framerate calculator is only 30ms.
- Suspect AIK Driver delay the grabbing time, checking this with Basler AIK engineer from Germany. 


Solution:
- Provide the sample code to show him how to use the basler API with Pylon AIK driver.
- Sample code: G:\Team Drives\202 Support\05 Programming code\Basler_Cognex_AIK_Driver
- Test on another Basler camera (4 megapixel CMOSIS sensor) show no problem of acquisition , which takes 30milliseconds between trigger pulse and image available in the PC .